Remove and Replace
6-34
WFM90D and WFM91D Service Manual
Remove. To remove the turnlock stud receptacle:
1. Remove the bottom cover. Refer to Bottom Cover on page 6--31.
2. Depress the retaining fingers on the turnlock stud receptacle and push the
receptacle through the bottom cover. See Figure 6--16.
Remove. To replace the turnlock stud receptacle:
1. Push the turnlock stud receptacle through the bottom cover. Be sure the
retaining fingers snap into position. See Figure 6--16.
2. Install the bottom cover. Refer to Bottom Cover on page 6--31.
Remove. To remove the electrical shield:
1. Remove the bottom cover. Refer to Bottom Cover on page 6--31.
2. Pry up the electrical shield on the inside of the bottom cover around the
edges and peel it off of the bottom cover.
3. If necessary, clean the surface of the bottom cover to remove any remaining
glue residue.
Replace. To replace the electrical shield:
1. Peel the protective covering off the adhesive surface of the electrical shield.
2. Position the electrical shield above the inside of the bottom cover and align
the hole in the shield with the hole in the bottom cover.
3. Press the shield onto the bottom cover and rub the shield to make sure it is
securely in place.
4. Install the bottom cover. Refer to Bottom Cover on page 6--31.