Remove and Replace
WFM90D and WFM91D Service Manual
6-25
Battery Cover Assembly
The battery cover assembly contains replaceable subparts. Procedures for
removing the subparts are included.
Remove. To remove the battery cover assembly:
1. Turn the turnlock stud 1/4-turn counterclockwise.
2. Pull outwards on the upper portion of the battery cover.
Replace. To replace the battery cover assembly:
1. Place the lower lip of the battery cover into the instrument housing and press
the top portion of the cover into the instrument. See Figure 6--11 on
page 6--26.
2. Secure the battery cover by turning the turnlock stud 1/4-turn clockwise.
Remove. To remove the carrying strap:
1. Remove the battery cover. Refer to Battery Cover on page 6--25.
2. To remove the carrying strap, remove the two retaining nuts on the inside of
the battery cover and pull the carrying strap off of the cover.
Replace. To replace the carrying strap:
1. Insert the two standoff studs of the carrying strap through the battery cover
and install the two retaining nuts.
2. Install the battery cover. Refer to Battery Cover on page 6--25.
Battery Cover