Remove and Replace
WFM90D and WFM91D Service Manual
6-21
To remove the SDI Interface board:
1. Remove the top cover. Refer to Top Cover on page 6--5.
2. Remove the battery cover. Refer to Battery Cover on page 6--25.
3. Lift on the Bottom board while pressing on the battery connector in the
battery compartment.
4. Disconnect the 20-pin cable from J7 on the Input board. See Figure 6--9.
5. Remove the SDI Interface board from the slot in the bottom cover.
SDI Interface board
Backlight board
J7
on Input board
20-pin cable
Figure 6- 9: Installing the SDI Interface board
To replace the SDI Interface board, reverse the removal procedure.
SDI Interface Board