WFM 90 & WFM 91 User Manual
3–9
Making Measurements
This section contains descriptions of the different graticules provided
with the WFM 90 and WFM 91 and methods for using them to
perform basics signal measurements.
This monitor uses a proprietary rasterizer to display the graticules.
The internal graticule scales are on the same plane as the CRT
phosphor, eliminating parallax errors.
Waveform Graticule
There are two versions of the Waveform display mode graticule,
illustrated in Figure 3–1 and Figure 3–2:
NTSC composite video graticule (WFM90 only)
PAL (CCIR) composite video graticule (WFM91 only)
Horizontal Scale
The 0 IRE (0.3 V PAL) graticule line is divided into 12 major
divisions. Each division represents a unit of time determined by the
SWEEP and MAG settings. Line-sweep rates appear in the on-screen
readout, and are as follows:
SWEEP
MAG ONTIME/DIV
1H (1LINE)
2H (2LINE)
5S/D
iv
10S/Div 1S/Div
0.5S/Div
In
2F (two field) sweep with MAG on, the signal is magnified by X20,
and the entire vertical interval can be viewed.